An MIC concentration is the lowest drug concentration, in mg/L (the same as µg/mL), at which a bacterial strain shows no visible growth after overnight incubation. In practice you do not pick it, you bracket it: a two-fold dilution series of 10 to 14 wells that must start above the likely MIC and end below it, run against every strain in the panel. Choosing that range badly is the most common reason a plate has to be repeated.
What concentration range should you test?
Broth microdilution, the reference method described in CLSI M07 and ISO 20776-1, doubles the concentration at each step and inoculates each well at about 5 x 105 CFU/mL. A series from 64 down to 0.125 mg/L gives ten wells. If the strain grows in every well, the MIC is above 64 and you report it as greater than 64, which tells you the compound is inactive at any usable dose but costs you the plate. If nothing grows even in the last well, the MIC is at or below 0.125 and you have lost the exact value.
| Well | Concentration, mg/L | Reading after 16 to 20 hours |
|---|---|---|
| 1 | 64 | No growth |
| 2 | 32 | No growth |
| 3 | 16 | No growth |
| 4 | 8 | No growth |
| 5 | 4 | No growth, this is the MIC |
| 6 | 2 | Growth |
| 7 | 1 | Growth |
| 8 | 0.5 | Growth |
| 9 | 0.25 | Growth |
| 10 | 0.125 | Growth |
In this example the first clear well is at 4 mg/L, so the MIC concentration is 4 mg/L. The method tolerates one dilution of scatter either way, so a repeat reading of 2 or 8 mg/L is the same result, not a failure. Only a two-dilution difference between replicates is worth chasing.
How much plate does one compound use?
A standard 96-well plate has eight rows and twelve columns, so one row holds a dilution series of up to twelve steps for one compound and one strain. A compound tested against six strains in duplicate takes twelve rows, which is a plate and a half before controls. A twenty compound hit list against that panel is thirty plates, and each plate needs a growth control and a sterility control per strain.
That arithmetic is why teams predict first. A predicted MIC band per strain tells you which compounds can be ruled out before any plate is poured and which ones deserve a narrow range centered where the model puts them, so a tested series wastes fewer wells on the extremes. The per compound cost of the prediction step is worked out on antibacterial screening software pricing.
How do you set the range for a new scaffold?
Start wide for a scaffold with no data: 128 down to 0.06 mg/L is 12 wells, one full row. Run it once against two reference strains, one Gram-positive such as S. aureus ATCC 29213 and one Gram-negative such as E. coli ATCC 25922, both of which are the quality control strains used in CLSI and EUCAST practice. Once you know roughly where the MIC falls, shrink to six or seven wells around it and add more strains in the same space. Gram-negatives that are efflux-rich, such as P. aeruginosa, usually sit several dilutions above E. coli for the same compound.
Reading an MIC concentration against a breakpoint
An MIC is not a verdict until it meets a breakpoint, the threshold that a standards body sets for a drug and species. CLSI publishes them in M100 and EUCAST in its breakpoint tables, and a value of 4 mg/L can be susceptible for one drug and resistant for another. For a research compound there is no breakpoint yet, so teams compare to a reference antibiotic in the same plate, which is why a comparator row belongs on every run. The mechanics of the read-out itself are in how MIC is measured and the definition in minimum inhibitory concentration explained.
From a SMILES string to a predicted concentration band
Antibacterial returns a predicted MIC band per strain, in doubling dilutions rather than one falsely precise number, along with the likely resistance mechanism and a confidence on every row. You paste a structure, pick a panel and read the matrix on the MIC prediction software page. The Lab plan is $149 a month, published with every other plan and started by card. A whole library goes through compound library screening software.
Questions buyers ask about MIC concentration
What does MIC concentration mean?
It is the lowest concentration of an antibacterial agent that prevents visible growth of a strain after incubation, usually 16 to 20 hours. It is reported in mg/L, equivalent to µg/mL, and always belongs to a specific compound and strain pair, never to a compound alone.
What concentration range is used for an MIC test?
A two-fold dilution series, commonly 64 to 0.125 mg/L for known drugs and 128 to 0.06 mg/L for a new scaffold. The range must bracket the true MIC, so a series that shows growth in every well or in none gives only a bound and has to be repeated with a shifted range.
Is a lower MIC always better?
Not on its own. A low MIC against one strain can come with high cytotoxicity or poor exposure in vivo, and the comparison only holds across the same method and strains. Breakpoints and the compound's achievable concentration in tissue decide whether a value is useful.
Can MIC concentration be predicted before testing?
Yes, as a band. A model trained on tested compounds can place a new structure within a few dilutions per strain, which is enough to rank a library and choose a test range. It does not replace the plate for the compounds you advance, and a novel scaffold gets a wider band with lower confidence.
Budgeting the rest of the stack around the plate is covered in drug discovery software cost, and the CLSI documents are on the CLSI site.