Skip to content
Antibacterial

MIC concentration range to test and what each compound costs

A badly chosen dilution range sends a plate back to the bench. Here is the range, a worked series, the plate count per compound and how a predicted band narrows it.

20 November 2026 6 min read Screening

Run a screen

of 3 left

Strain panel

No account needed. 3 screens per session.

Sample output Ciprofloxacin Fluoroquinolone
Worked example, replaced when you run
Strain MIC (µg/mL) Call Resistance risk Conf.
S. aureus (MRSA) 0.5->32 R Resistant target mutation, grlA and gyrA Fluoroquinolone resistance is widespread in methicillin resistant lineages.
E. coli <=0.015-0.06 S Susceptible efflux, AcrAB-TolC in resistant isolates Potent against wild type; qnr carriage and gyrA changes shift the band sharply.
K. pneumoniae (CRE) 0.5->64 R Resistant gyrA mutation with plasmid qnr Carbapenemase producing isolates almost always carry quinolone resistance too.
A. baumannii 8->64 R Resistant efflux, AdeABC Constitutive efflux plus target changes leave little room at achievable exposure.
P. aeruginosa 0.25-2 I Intermediate efflux, MexAB-OprM Borderline: active on many isolates, lost quickly once efflux is derepressed.
E. faecium (VRE) 4->32 R Resistant target mutation, parC Enterococci are intrinsically poor fluoroquinolone targets.

Why

Ciprofloxacin is a well characterised fluoroquinolone, so the Gram-negative bands are strongly supported by published activity data. The deciding factor across this panel is not target affinity but exposure: efflux in P. aeruginosa and A. baumannii, and acquired target mutation everywhere resistance is already common. Against a modern ESKAPE panel it reads as a Gram-negative agent with two reliable losses.

Closest published analogs

  • Levofloxacin Broadly similar Gram-negative bands, better Gram-positive coverage
  • Delafloxacin Retains activity against many ciprofloxacin resistant staphylococci
Strain MIC (µg/mL) Call Resistance risk Conf.

Why

Closest published analogs

Want the rest of your series? Batch runs are on the paid tiers. screen left in this session. This session is used up.

Computational prediction from published literature. Research use only, not a lab measurement and not clinical guidance.

An MIC concentration is the lowest drug concentration, in mg/L (the same as µg/mL), at which a bacterial strain shows no visible growth after overnight incubation. In practice you do not pick it, you bracket it: a two-fold dilution series of 10 to 14 wells that must start above the likely MIC and end below it, run against every strain in the panel. Choosing that range badly is the most common reason a plate has to be repeated.

What concentration range should you test?

Broth microdilution, the reference method described in CLSI M07 and ISO 20776-1, doubles the concentration at each step and inoculates each well at about 5 x 105 CFU/mL. A series from 64 down to 0.125 mg/L gives ten wells. If the strain grows in every well, the MIC is above 64 and you report it as greater than 64, which tells you the compound is inactive at any usable dose but costs you the plate. If nothing grows even in the last well, the MIC is at or below 0.125 and you have lost the exact value.

Well Concentration, mg/L Reading after 16 to 20 hours
1 64 No growth
2 32 No growth
3 16 No growth
4 8 No growth
5 4 No growth, this is the MIC
6 2 Growth
7 1 Growth
8 0.5 Growth
9 0.25 Growth
10 0.125 Growth

In this example the first clear well is at 4 mg/L, so the MIC concentration is 4 mg/L. The method tolerates one dilution of scatter either way, so a repeat reading of 2 or 8 mg/L is the same result, not a failure. Only a two-dilution difference between replicates is worth chasing.

How much plate does one compound use?

A standard 96-well plate has eight rows and twelve columns, so one row holds a dilution series of up to twelve steps for one compound and one strain. A compound tested against six strains in duplicate takes twelve rows, which is a plate and a half before controls. A twenty compound hit list against that panel is thirty plates, and each plate needs a growth control and a sterility control per strain.

That arithmetic is why teams predict first. A predicted MIC band per strain tells you which compounds can be ruled out before any plate is poured and which ones deserve a narrow range centered where the model puts them, so a tested series wastes fewer wells on the extremes. The per compound cost of the prediction step is worked out on antibacterial screening software pricing.

How do you set the range for a new scaffold?

Start wide for a scaffold with no data: 128 down to 0.06 mg/L is 12 wells, one full row. Run it once against two reference strains, one Gram-positive such as S. aureus ATCC 29213 and one Gram-negative such as E. coli ATCC 25922, both of which are the quality control strains used in CLSI and EUCAST practice. Once you know roughly where the MIC falls, shrink to six or seven wells around it and add more strains in the same space. Gram-negatives that are efflux-rich, such as P. aeruginosa, usually sit several dilutions above E. coli for the same compound.

Reading an MIC concentration against a breakpoint

An MIC is not a verdict until it meets a breakpoint, the threshold that a standards body sets for a drug and species. CLSI publishes them in M100 and EUCAST in its breakpoint tables, and a value of 4 mg/L can be susceptible for one drug and resistant for another. For a research compound there is no breakpoint yet, so teams compare to a reference antibiotic in the same plate, which is why a comparator row belongs on every run. The mechanics of the read-out itself are in how MIC is measured and the definition in minimum inhibitory concentration explained.

From a SMILES string to a predicted concentration band

Antibacterial returns a predicted MIC band per strain, in doubling dilutions rather than one falsely precise number, along with the likely resistance mechanism and a confidence on every row. You paste a structure, pick a panel and read the matrix on the MIC prediction software page. The Lab plan is $149 a month, published with every other plan and started by card. A whole library goes through compound library screening software.

Questions buyers ask about MIC concentration

What does MIC concentration mean?

It is the lowest concentration of an antibacterial agent that prevents visible growth of a strain after incubation, usually 16 to 20 hours. It is reported in mg/L, equivalent to µg/mL, and always belongs to a specific compound and strain pair, never to a compound alone.

What concentration range is used for an MIC test?

A two-fold dilution series, commonly 64 to 0.125 mg/L for known drugs and 128 to 0.06 mg/L for a new scaffold. The range must bracket the true MIC, so a series that shows growth in every well or in none gives only a bound and has to be repeated with a shifted range.

Is a lower MIC always better?

Not on its own. A low MIC against one strain can come with high cytotoxicity or poor exposure in vivo, and the comparison only holds across the same method and strains. Breakpoints and the compound's achievable concentration in tissue decide whether a value is useful.

Can MIC concentration be predicted before testing?

Yes, as a band. A model trained on tested compounds can place a new structure within a few dilutions per strain, which is enough to rank a library and choose a test range. It does not replace the plate for the compounds you advance, and a novel scaffold gets a wider band with lower confidence.

Budgeting the rest of the stack around the plate is covered in drug discovery software cost, and the CLSI documents are on the CLSI site.

From the note to a read-out

Screen the compound this note made you think about. Three screens per session, no account, and the full matrix every time.

Run a screen first

What you are agreeing to

  • Your compounds stay yours
  • Never used for model training
  • Deletable on request
  • No card needed to create your account

Screen your own compound.
No card required.